Isuzu power plant
Isuzu power plant
Genset Technical Parameters | ||||
Genset Model | ISU20 | ISU25 | ISU22 | ISU27 |
Constant Power(KW) | 20 | 25 | 22 | 27 |
3-phase/400V/50Hz | 3-phase/400V/50Hz | |||
Engine Model | 4JB1 | 4JB1T | 4JB1 | 4JB1T |
1500,50Hz | 1800,60Hz | |||
Engine Parameters | Water-cooling, 4-stroke,Direct Injection, | |||
Rated Output(KW) | 24 | 28 | 28 | 34 |
Aspiration | Natural Aspiration | Turbocharged | Natural Aspiration | Turbocharged |
Bore*Stroke(mm) | 93x102 | 93x102 | 93x102 | 93x102 |
Displacement(L) | 2.771 | 2.771 | 2.771 | 2.771 |
Compression Ratio | 18.2:1 | 18.2:1 | 18.2:1 | 18.2:1 |
Steady governing ratio | less than 5% | less than 5% | less than 5% | less than 5% |
Brake Mean Effective Pressure (kPa) Rated Power | 750 | 895 | 746 | 890 |
Coolant Heat | 21.6kW/min | 26.8 kW/min | 27.1 kW/min | 30.7 kW/min |
Aspiration Flow | 96m3/min | 96m3/min | 118m3/min | 118m3/min |
Fuel Consumption(L/h) | 5.6 | 6.4 | 6.5 | 7.8 |
Voltage Regulation Rate in steady | ≤±1.0% | |||
Waveform Distortion | No-loadless than 1.5% | |||
Radiation Interference | THF less than2%,TIF less than50 |
Specifications:
1 Output range: 18Kw to 30Kw
2 Available Engine: Isuzu
3 Alternator model:
a) Stamford\Leroy Somer\ENGGA\Branch Stamford and Branch Leroysomer
4 Small volume, light weight, low noise, low fuel consumption, water cooling
with water tank and fan\air cooling
5 Key start / auto start
6 Monitoring meters and control switches
7 Protection provided for short, over-current, over-speed, high water temperature
and low oil pressure
8 Soundproof / weatherproof canopy optional
9 Standard parts: industrial type silencers, exhaust pipes, flexible exhaust bellows,
vibration-damping rubber, lead-acid batteries, connective cables, user manual
and technical papers
Control system:
1 a) Automatic alarm system: the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current b) Operation display: i) Unit voltage, tri-phase load current and frequency display ii) Water temperature, oil pressure display iii) Fuel level, fuel temperature display iv) Audible and visual alarm lamps and buzzers2 Starting system: DC alternator is used to start engine3 Short circuit protection: MCCB air switch4 Cooling system: combined cooling water tank fitted to meet the requirement of radiation at ambient temperature 40°C5 Filter system: oil, fuel and air filter6 Accessories: exhaust elbow, bellow, muffler
Supply standard configure:
a) Diesel engine with all accessories, 3 filter, electric systems b) Alternatorc) Steel structure
d) Fan and water tank cooling system
e) Flange connectorf) 12 / 24V starting motor and charge engine
g) Air cleaner, fuel cleaner, oil cleaner
h) On-board control panel
i) MCCB air conservation switch
j) 12 / 24V starting accumulator and Battery line
k) Set shock absorber
l) High-efficient silencer
Parameters:
1) Rated voltage: 400 / 230V, 220/127V
2) Rated Frequency: 50Hz/60Hz
3) Mode of connection: 3-phase-4-line
4) Rated power factor: 0.8 (lagging)
Isuzu power plant